VESA mount for Eakins trinocular stereo microscope

STL file downloaded from: https://www.thingiverse.com/thing:4853500

Printed on a Prusa i3 MK2 in PLA, 0.2 mm resolution, 25% honeycomb infill.

Some instructions and pictures of the conversion.

Hot off the printer. Just needed a tidy and the holes cleaned up with a 10mm drill bit.
Original focusing rack
Remove the Allen head screw
Move the rack until these two screws are visible and remove them. Move the rack the other way and remove the two screws at the other end.
Turn the knob until the insert pops out the top.
Keep turning the knob until the two parts of the assembly separate.
Watch out you don’t lose these small plastic spacers
Unscrew one of the knobs (labelled “tension”) and pull out the other with rod attached.
.
There are a couple of plastic washers on each side. Don’t lose them.
Press out the plastic bearings from the inside using a small screw driver
And press them into the print. You may need to tidy up the holes with a 10mm drill bit.
Refit the knobs not forgetting the washers
Join the two halves together and feed the plastic insert into the top. Turn the knob until the two plastic spacers are visible and make sure the screw holes line up. You can put the spacers back in at this point if they have fallen out.
Turn the knob until the screw holes in the plastic insert align with those in the body. Then insert and tighten screws. Then do the same at the other end.
Center the rack and insert the end-stop screw.

All done!

4 thoughts on “VESA mount for Eakins trinocular stereo microscope”

    1. I printed out another design, the universal 25mm adapter and my scope dropped to the desk within three hours of mounting. Had to put it back together and thankfully no lasting damage.

      Is this design strong enough to last? Do I need to use petg-cf at 65% infill?

      Also, not sure how this design holds up the scope. Where is the weight bearing part of the design that holds the weight?

      1. Well mine has been in regular use for the last 4 years and looks newly printed!
        I only used PLA with 25% infill. Maybe you had poor layer adhesion? Try raising the print temperature and drying the filament.

        This design replaces the original mount so can better handle the shear forces than an adapter.